Your cart is empty.
Browse Products2 Ton Rheem 16 SEER2 R-454B 96% AFUE 60,000 BTU Two-Stage Variable Speed Multi-Position Gas Furnace Split System
$7,172.56
-
- Free shipping — most items ship by the next day
Licensed HVAC technician required. Must be installed by a certified professional. Improper installation voids the manufacturer warranty.
Licensed HVAC technician required. Must be installed by a certified professional. Improper installation voids the manufacturer warranty.
- Free shipping — most items ship by the next day
$7,172.56
-
- Free shipping — most items ship by the next day
This is a matched Rheem 2-ton cooling / ~56k BTU heating residential split system using low-GWP R-454B refrigerant. It pairs a two-stage outdoor air conditioner with a multi-position cased coil and a high-efficiency two-stage variable-speed gas furnace for year-round comfort, efficiency, and installation flexibility.
Rheem Endeavor Line Classic Plus Series 2-Ton 16 SEER2 Two-Stage Air Conditioner (R-454B) RA16AY24AJ2NA
- Two-stage scroll compressor for precise temperature control, better humidity management, and higher efficiency than single-stage units.
- 7 mm copper condenser coil (requires less refrigerant, smaller/lighter footprint, enhanced reliability).
- Swept-wing fan technology for quieter operation.
- PlusOne Expanded Valve Space (3–4–5 in service valve area, ~27 sq in working space).
- PlusOne Triple Service Access (15 in wide corner access, two-fastener removable corner, individual louver panels).
- PlusOne Refrigerant Detection System (integrated A2L sensor + mitigation board for simplified wiring and automatic outdoor unit shutdown if excess refrigerant is detected).
- Powder-coated finish, rust-resistant screws, external gauge ports.
- ENERGY STAR certified (when properly matched).
- 10-year conditional parts warranty (registration required).
- Runs mostly in lower stage for quieter, more efficient cooling with reduced temperature swings and better dehumidification.
- Lower environmental impact with R-454B (significantly lower GWP than R-410A).
- Easier installation and service access reduce labor time.
- Designed for long-term reliability and lower operating costs.
- Operating dimensions: 25 in H × 33.75 in W × 33.75 in D
- Shipping dimensions: approx. 26.5 in H × 36.38 in W × 36.38 in D
- Weight: ~184 lb (operating), ~190 lb shipping
- Nominal capacity: 24,000 BTU
- SEER2: up to 16–17 (system-dependent; matched ratings typically mid-14s depending on indoor match)
- Sound level: ~69–74.1 dBA
- Voltage: 208/230 V, 1-phase, 60 Hz
- Refrigerant: R-454B (factory charged ~103 oz)
- Liquid line: 3/8 in OD | Suction line: 3/4 in OD
- MCA: ~16 A | Max breaker: 25 A
Rheem/Ruud Endeavor RCFY Series 2-Ton (1.5–2 Ton) Multi-Position Cased Coil (R-454B) RCFY2417STANMC
- Aluminum fins bonded to internally grooved aluminum tubing.
- Factory TXV metering device.
- Multi-position (upflow, downflow, horizontal left/right) – bi-directional airflow, no internal component switching needed.
- Copper sweat refrigerant connections.
- Dual 3/4 in NPT condensate drain connections.
- High-grade, heat-resistant, corrosion-free thermal-set drain pan.
- Factory leak-tested; UV-resistant for germicidal light compatibility.
- Includes A2L refrigerant detection sensor (on most configurations).
- Designed for use with Rheem/Ruud outdoor units and gas/oil furnaces.
- Excellent heat transfer and corrosion resistance.
- Flexible installation in tight or varied spaces.
- Reliable condensate management and system protection with A2L sensor.
- Cabinet: 20–20.5 in H × 17.5 in W × 21.69 in D (approx. 20 in H × 17.5 in W × 21-11/16 in D)
- Weight: ~43 lb
- Nominal capacity: 24,000 BTU
- Face area: ~4.56 sq ft | 2-row coil | 16 FPI
- Liquid line: 3/8 in | Suction line: 3/4 in
- Airflow: typically 525–900 CFM (wet) / 600–1,200 CFM (dry) range depending on application
Rheem/Ruud Endeavor Line Classic Plus Series 96% AFUE Two-Stage Variable-Speed (Constant CFM) Gas Furnace R962V0603A17M4SCAP
- 96% AFUE ENERGY STAR certified.
- Two-stage gas valve (primarily operates at low fire ~60–65% for efficiency and comfort; stages up as needed).
- Variable-speed constant-CFM ECM blower motor (1/2 hp) for precise airflow, superior humidity control, quieter operation, and year-round energy savings.
- EcoNet enabled + Bluetooth diagnostics (contractor app support for setup, monitoring, and troubleshooting; dip-switch-free commissioning on many setups).
- PlusOne Ignition System (direct spark).
- PlusOne Water Management System (patented blocked-drain sensor that shuts unit down and alerts).
- 4-way multi-position (upflow, downflow, horizontal left/right).
- Aluminized steel primary heat exchanger + stainless steel secondary.
- Compatible with natural gas or propane (conversion kit may be required).
- Insulated blower compartment, solid bottom.
- Consistent temperatures and excellent humidity control.
- Lower energy bills and quieter performance vs. single-stage/PSC motors.
- Advanced diagnostics simplify service.
- High efficiency + flexible installation options.
- Cabinet: 34 in H × 17.5 in W × 28.125–29.625 in D
- Weight: ~128 lb
- Input: 56,000 BTU/h (high fire); ~39,200 BTU/h (low fire)
- Output: ~55,000 BTU/h
- Heating CFM (approx.): 1,100 (high) / 990 (low)
- Cooling CFM capability: up to ~1,125–1,250 (supports up to 3-ton AC)
- Voltage: 115 V, 1-phase, 60 Hz
- MCA: ~8–9 A | Max overcurrent: 15 A
- Temperature rise: 30–60 °F (high fire)
This combination delivers efficient two-stage cooling with modern low-GWP refrigerant, paired with a high-efficiency two-stage variable-speed furnace for precise year-round comfort. The matching 17.5 in cabinet widths simplify installation, multi-position flexibility suits a wide range of home layouts, and features like refrigerant detection, expanded service access, and EcoNet/Bluetooth diagnostics improve reliability and ease of maintenance. Proper AHRI-matched installation is required for rated performance, ENERGY STAR qualification, and warranty coverage.
Note: Exact system SEER2/EER2 and capacity depend on the specific AHRI-matched rating. Always confirm local codes, proper sizing (Manual J), and installation by a qualified technician. Specs are compiled from manufacturer data and may vary slightly by production run—verify with current Rheem/Ruud literature or submittal sheets.
- Matched Rheem Split System — 2-ton two-stage 16 SEER2 Endeavor Line air conditioner paired with a cased coil and gas furnace
- Two-Stage Scroll Compressor — high and low stages for precise temperature control and better humidity management
- Low-GWP R-454B Refrigerant — next-generation refrigerant with a lower global warming potential
- 96% AFUE Two-Stage Furnace — high-efficiency variable-speed gas furnace with multi-position installation
Genuine OEM parts
Easy online ordering
30-day hassle-free returns
Help when you need it
What buyers are saying
Verified reviews from customers who purchased this product.
No reviews yet
Be the first to share your experience with this product.