Your cart is empty.
Browse Products4 Ton Rheem 16 SEER2 R-454B 80% AFUE 100,000 BTU Two-Stage Variable Speed Upflow/Horizontal Gas Furnace Split System
$6,961.45
-
- Free shipping — most items ship by the next day
Licensed HVAC technician required. Must be installed by a certified professional. Improper installation voids the manufacturer warranty.
Licensed HVAC technician required. Must be installed by a certified professional. Improper installation voids the manufacturer warranty.
- Free shipping — most items ship by the next day
$6,961.45
-
- Free shipping — most items ship by the next day
This is a matched Rheem/Ruud Endeavor Line residential system using low-GWP R-454B refrigerant. It pairs a 4-ton two-stage air conditioner condenser with a multi-position cased evaporator coil and an 80% AFUE single-stage gas furnace with a variable-speed (constant CFM) ECM blower. The combination delivers efficient cooling with good humidity control and reliable heating, suitable for many homes needing 48,000 BTU cooling and 80,000–100,000 BTU heating capacity.
Rheem Endeavor Line Classic Plus Series 4-Ton 16 SEER2 Two-Stage Air Conditioner (R-454B) RA16AY48AJ2NA
Quieter cooling, more even comfort, lower operating costs, and a future-ready low-GWP refrigerant.
- Nominal capacity: 4 tons / 48,000 BTU
- Efficiency: Up to 16–17 SEER2 / ~12 EER2 (system-dependent; ENERGY STAR rated when properly matched)
- Refrigerant: R-454B (factory charge ~133 oz for 15 ft lines)
- Compressor: Two-stage scroll
- Electrical: 208/230V, 1-phase, 60 Hz; MCA 26 A; Max overcurrent 40 A
- Sound: ~73.2 dBA
- Liquid line: 3/8″; Suction line: 7/8″
- Dimensions (H × W × D): 35″ × 33.75″ × 33.75″
- Operating weight: ~248 lbs; Shipping weight: ~255 lbs
- Two-stage scroll compressor runs mostly in low stage for more consistent temperatures, better humidity control, and higher efficiency than single-stage units.
- Swept-wing fan + composite base pan for quieter operation and reduced vibration.
- 7 mm copper condenser coil uses less refrigerant, enables a more compact/lighter design, and improves reliability.
- PlusOne Expanded Valve Space (3-4-5″) and Triple Service Access (15″ wide corner access with removable panels) for easier installation and service.
- Durable powder-coated cabinet, rust-resistant fasteners, and external gauge ports.
- Supports long-line applications and low-ambient operation (with optional kit).
Rheem/Ruud Endeavor RCFY Series 4-Ton Multi-Position Cased N-Coil (R-454B, TXV) RCFY4821STANMC
Reliable heat transfer, flexible installation, and reduced risk of leaks or corrosion for lasting system performance.
- Nominal capacity: 3.5–4 tons / 48,000 BTU
- Metering device: Factory TXV
- Refrigerant: R-454B
- Cabinet width: 21″
- Airflow range: ~600–1,900 CFM
- Liquid line: 3/8″; Suction line: 7/8″
- Condensate drains: Dual 3/4″ NPT
- Dimensions (H × W × D): Approximately 28–28.5″ × 21″ × 21.7″ (21-11/16″)
- Weight: ~71 lbs (shipping ~78 lbs)
- All-aluminum construction (fins bonded to internally grooved tubing) for corrosion resistance and long life.
- Multi-position (upflow, downflow, horizontal left/right) with bi-directional airflow—no internal component swaps needed.
- N-coil design maximizes performance while keeping cabinet height compact.
- Factory leak-tested; copper sweat connections; high-grade composite drain pan resistant to heat and corrosion.
- UV-resistant and compatible with germicidal lights; factory A2L sensor option for R-454B systems.
Rheem/Ruud Endeavor Line Classic Series 80% AFUE Single-Stage Gas Furnace with Variable-Speed ECM (Upflow/Horizontal) R801V1005A21UHSCAP
Comfortable, quieter heating with efficient airflow that pairs well with the two-stage AC for year-round performance and potential energy savings.
- Input: 100,000 BTU/h
- Output: 80,000 BTU/h
- AFUE: 80%
- Stages: Single-stage gas valve
- Blower: 3/4 HP constant-CFM / variable-speed ECM (up to ~1,980 CFM cooling / ~1,380 CFM heating)
- Configuration: Upflow / Horizontal
- Cabinet width: 21″
- Electrical: 115V, 1-phase, 60 Hz; MCA ~12–13 A
- Temperature rise: 35–65 °F
- Dimensions (H × W × D): 34″ × 21″ × ~29.6″
- Weight: ~140 lbs
- Variable-speed (constant CFM) ECM blower provides quieter operation, better humidity control in cooling mode, and more consistent airflow.
- EcoNet-enabled with Bluetooth diagnostics and PlusOne features for easier commissioning, monitoring, and service via contractor/homeowner apps.
- Direct spark ignition for reliability.
- Fully insulated cabinet and solid bottom for reduced noise.
- Compatible with natural gas or LP (conversion kits available); supports 3–5 ton cooling.
When properly matched and installed, this combination provides solid SEER2 cooling efficiency (typically in the mid-teens depending on exact AHRI match), reliable 80% AFUE heating, and modern features focused on comfort, quieter operation, and serviceability. Always verify the specific AHRI-rated match for exact efficiency numbers, confirm local code compliance (including A2L refrigerant requirements), and have a qualified technician size and install the system. Dimensions and weights are approximate based on manufacturer data.
- Matched Rheem Split System — 4-ton two-stage 16 SEER2 Endeavor Line air conditioner paired with a cased coil and gas furnace
- Two-Stage Scroll Compressor — high and low stages for precise temperature control and better humidity management
- Low-GWP R-454B Refrigerant — next-generation refrigerant with a lower global warming potential
- 80% AFUE Gas Furnace — single-stage furnace with a variable-speed ECM blower in an upflow/horizontal cabinet
Genuine OEM parts
Easy online ordering
30-day hassle-free returns
Help when you need it
What buyers are saying
Verified reviews from customers who purchased this product.
No reviews yet
Be the first to share your experience with this product.




