Quick specs
Heating Capacity
15 kW
Refrigerant
A2L-compatible
Brand
Frigidaire
Not sure this fits your unit?
Call us with your model number and we'll confirm the right part before you order.
SKU: HK1-15K-01A · Category: MAYTAG

FRIGIDAIRE 15 kW A2L Heat Kit HK1-15K-01A

15 kW Supplemental Heat·A2L Compliant

$355.28

-

  • Free shipping — most items ship by the next day

Licensed HVAC technician required. Must be installed by a certified professional. Improper installation voids the manufacturer warranty.

Secure payment
VISA MC AMEX DISC PayPal Affirm CHECK
SKU: HK1-15K-01A · Category: MAYTAG
FRIGIDAIRE 15 kW A2L Heat Kit HK1-15K-01A
Quick specs
Heating Capacity
15 kW
Refrigerant
A2L-compatible
Brand
Frigidaire
Not sure this fits your unit?
Call us with your model number and we'll confirm the right part before you order.

The Frigidaire HK1-15K-01A is a factory accessory electric heat kit for packaged air conditioners and packaged heat pumps. It installs inside the unit’s electric-heat compartment and adds supplemental resistance heat when the outdoor unit cannot keep up or when electric heat is the primary heat source. Heating elements energize, the packaged unit blower moves air across them, and warm air is delivered through the duct system.

This Frigidaire kit is A2L-compliant and approved for use with both R-454B and R-410A packaged units. Older Frigidaire H3HK kits are not approved for R-454B.

Features and benefits

  • 15 kW / 45,126 BTU/h supplemental electric heat for packaged AC and heat pump applications
  • 208/230V, 1-phase, 60 Hz — matches standard residential packaged-unit power
  • A2L-approved components — safe for R-454B and R-410A refrigerant systems (H3HK kits are not)
  • Factory 9-pin heater plug for straightforward connection to the unit heat accessory harness
  • Dual-circuit design typical of 15 kW kits; optional field staging on 15 kW / 20 kW models
  • Main and backup limit controls for over-temperature protection
  • Zero clearance to combustibles when installed per the unit and kit instructions
  • Designed as a drop-in accessory: remove close-off plates, mount elements closest to the blower, land power on the kit terminal block or unit-mounted breakers
  • Restores or adds heat capacity without replacing the entire packaged unit

Minimum airflow for a ~40°F temperature rise: 1,045 CFM (1,775 m³/h). Target rise is generally 30–40°F; avoid exceeding 40°F.

Electrical (typical)

  • Voltage: 208/230 VAC, 1-phase, 60 Hz
  • Capacity: 15 kW (45,126 BTU/h)
  • Circuits: 2-circuit (HK1-15K-01A); 3-circuit variant is HK1-15K-21A
  • Accessory circuit breakers (2-pole, 1-phase): P/N 913554
  • Optional 4-pole single-circuit adapter: P/N 913350
  • Overcurrent protection and MCA must follow the packaged unit rating plate and Tables in the HK1 installation instructions
  • Use copper conductors rated 60°C minimum

Exact MCA/MOP change with the host unit size and whether breakers or a single-circuit adapter are used. Always size branch-circuit protection from the unit nameplate after the kit is installed.

Dimensions and installation notes

This is an internal accessory kit, not a standalone cabinet. It mounts in the packaged unit electric-heat panel.

  • 15 kW / 20 kW kits include a contactor bracket that fastens to the blower transition panel
  • Element support rod must seat in the support bracket
  • Horizontal supply/return: install with the limit toward the top of the unit
  • Vertical supply/return: follow kit instructions for 15 kW orientation; rooftop vertical discharge needs an elbow so elements are not directly over a grille
  • Position heater banks closest to the blower
  • Mark the installed heater kit on the unit rating plate

Compatibility

Approved for Nortek / Frigidaire / Maytag / AireForce HK1-series packaged air conditioners and packaged heat pumps when applied per the HK1 installation manual including families such as:

  • (*)P94RD single-phase packaged units
  • (*)P95RD single-phase packaged units
  • (*)Q94RD single-phase packaged units
  • (*)Q95RD single-phase packaged units
  • (*)Q104SD single-phase packaged units

Installation must be performed by a licensed HVAC technician. Follow the HK1 Series A2L installation instructions and the packaged unit IOM for wiring, airflow, and code requirements.

Key features
  • 15 kW Supplemental Heat — adds electric resistance heat to packaged ACs and heat pumps
  • A2L Compliant — approved for use with A2L refrigerant systems
  • Installs Inside the Unit — mounts in the packaged unit's electric-heat compartment
  • Built-In Limit Controls — protects the unit and the home

Why homeowners choose NAW

Genuine OEM parts

Every part we sell is the real thing — authorized, factory-genuine, and backed by the full manufacturer warranty.

Easy online ordering

Find your part by model number, add to cart, and get it delivered to your door — no middleman, no markup.

30-day hassle-free returns

Ordered the wrong part? Send it back within 30 days.

Help when you need it

Not sure if this is the right part? Call us at (888) 292-0874 and we’ll help you find the correct replacement.
Specifications
Voltage / Phase / Frequency 208/230 VAC, 1-phase, 60 Hz
Heat Output 45,126 BTU/h
Circuits 2-circuit
Heater Plug 9-pin
Min. Airflow (~40°F rise) 1,045 CFM (1,775 m³/h)
Conductors Copper, 60°C minimum
Refrigerant Approval R-454B and R-410A packaged units