Quick specs
Part Number
ICM2812-KIT
Part Type
Universal HSI furnace control board kit
Brand
ICM Controls
Control Voltage
24 VAC
Ignition
Hot surface ignition (HSI)
Fits
Universal; replaces White-Rodgers 50M56U-843 and 200+ OEM boards
Not sure this fits your unit?
Call us with your model number and we'll confirm the right part before you order.
SKU: ICM2812-KIT · Category: INTEGRATED FURNACE CONTROL (IFC) BOARDS

ICM CONTROLS Universal Replacement Furnace Control Board Kit ICM2812-KIT

Universal HSI Furnace Control·Cable Harnesses Included

$207.68

-

  • Free shipping — most items ship by the next day

Licensed HVAC technician required. Must be installed by a certified professional. Improper installation voids the manufacturer warranty.

Secure payment
VISA MC AMEX DISC PayPal Affirm CHECK
SKU: ICM2812-KIT · Category: INTEGRATED FURNACE CONTROL (IFC) BOARDS
ICM CONTROLS Universal Replacement Furnace Control Board Kit ICM2812-KIT
Quick specs
Part Number
ICM2812-KIT
Part Type
Universal HSI furnace control board kit
Brand
ICM Controls
Control Voltage
24 VAC
Ignition
Hot surface ignition (HSI)
Fits
Universal; replaces White-Rodgers 50M56U-843 and 200+ OEM boards
Not sure this fits your unit?
Call us with your model number and we'll confirm the right part before you order.

The ICM ICM2812-KIT is a low-cost universal Hot Surface Ignition (HSI) furnace control that replaces White-Rodgers 50M56U-843 and 200+ OEM boards. The kit includes the control plus a set of cable harnesses so you can match the original connector instead of cutting and splicing. That cuts install time and reduces callback risk on common Goodman, Carrier, Lennox, York, Trane, Rheem, Nordyne, and White-Rodgers furnaces.

A microprocessor-based board runs the full heat sequence: inducer timing, ignitor warm-up, trial for ignition, flame sensing, gas valve control, blower delays, and lockout. Built-in LED status and fault codes speed diagnosis on the job. 100% lockout safety and compatibility with natural gas or LP keep the replacement in line with typical residential gas furnace operation. Use it when the original board has failed and you want one stocked kit that covers a wide range of single-stage HSI applications.

Key specs

  • Control voltage: 24 VAC (18–30 VAC)
  • Line voltage: 120 VAC
  • HSI output: 6 A @ 120 VAC
  • Gas valve: 1.5 A @ 24 VAC
  • Inducer: 2.2 FLA @ 120 VAC
  • Blower: 14.5 FLA @ 120 VAC
  • Operating temperature: −40° to 176°F (−40° to 80°C)
  • Humidity: 5–95% RH, non-condensing

Dimensions & weight

  • Length: 5.15 in
  • Width: 7.65 in
  • Height: 1.26 in
  • Weight: 1 lb

Compatibility The kit is a universal HSI furnace control with included harnesses. It is intended as a replacement for White-Rodgers 50M56U-843 and 200+ related boards, including common numbers from:

  • White-Rodgers: 50A50, 50A55, 50A56, 50A65, 50A66, 50M56, 50T35, 50T55 series (including 50A50-112, 50A55-843, 50M56-743, and many others)
  • Goodman / Amana: 10207701, 10207704, 10207706, 10207710, 10207714, 10207717–20, 0130F00005(S), 0130F00006(S), B1809926(S), PCBBF109 / 110 / 112 / 122 / 123 / 132 / 134–138 and related
  • Carrier: HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ016
  • Lennox: 10M93, 12L69, 17W92, 23W51, 30W25, 32M88, 56L84, 69M08, 69M15, 100925, 1214201, X4459 and related
  • York / Coleman / Luxaire / Evcon / JCI: G951ADB / G951AEB series, 031-00662, 031-01250, 031-01266, 031-01284, S1-0310… harness families and related
  • Trane / American Standard: CNT02789, CNT02891, CNT03076, CNT03798, CNT03799, CNT05164, CNT05165, D330927P01, D341122P01, D341235P01, D341396P01 and related
  • Rheem / Ruud: 695-200, 62-22694-xx, 62-22732-xx, 62-24044-xx, 62-24045-01, 62-24046-01, 62-24084-82, 62-24268
  • Nordyne: 624557, 624564, 624591, 624628, 624631(A), 710128A, 902378, 902696, 903106 (120 VAC models only)
  • Also listed: selected Heil/ICP, Whirlpool, Thermo Products, Texas Instruments, and United Technologies boards

Always match the original part number and furnace wiring diagram before install. Some Rheem/Ruud units without a separate flame sensor need Rheem flame sensor kit 62-24044-71. Follow ICM harness notes for Trane/American Standard and certain York models. Professional installation is recommended.

Key features
  • Universal HSI Furnace Control — replaces White-Rodgers 50M56U-843 and 200+ OEM boards
  • Cable Harnesses Included — match the original connector without cutting or splicing
  • Faster Installs — reduces install time and callback risk
  • Wide Brand Coverage — Goodman, Carrier, Lennox, York, Trane, Rheem, Nordyne and more

Why homeowners choose NAW

Genuine OEM parts

Every part we sell is the real thing — authorized, factory-genuine, and backed by the full manufacturer warranty.

Easy online ordering

Find your part by model number, add to cart, and get it delivered to your door — no middleman, no markup.

30-day hassle-free returns

Ordered the wrong part? Send it back within 30 days.

Help when you need it

Not sure if this is the right part? Call us at (888) 292-0874 and we’ll help you find the correct replacement.
Specifications
Control Voltage 24 VAC (18-30 VAC)
Line Voltage 120 VAC
HSI Output 6 A @ 120 VAC
Gas Valve 1.5 A @ 24 VAC
Inducer / Blower 2.2 FLA / 14.5 FLA @ 120 VAC
Operating Temperature -40° to 176°F (-40° to 80°C)
Dimensions (L x W x H) 5.15 x 7.65 x 1.26 in
Weight 1 lb