OEM Trane / American Standard single-stage furnace control board for 120V hot-surface ignition systems. The CNT07941 runs the heat sequence, monitors limits and the pressure switch, and switches the inducer, gas valve, ignitor, and indoor blower. It is the current board used on many 2000-and-later single-stage furnaces, including the Ameristar M951P series.
Features
- Single-stage integrated furnace control
- 120V hot-surface ignition (HSI)
- Single-speed inducer output
- On-board 5 amp fuse
- LED status and fault indication for troubleshooting
- Direct replacement for CNT07541 and related earlier boards
- For furnaces produced in 2000 or later (1999 and earlier units may require CNT07943)
Replaces / supersedes CNT07541, CNT-7541, CNT7541, CNT03797, CNT-3797, CNT02789, CNT-2789, CNT03606, CNT-3606, BAF00434, BAF0434, D345780P01, 50M56-495-04, 50M56-495, 50A55-474, and 56-7457A.
Also known as CNT-7941 and CNT7941. White-Rodgers / Emerson cross-reference: 50M56-495-04.
Common applications
- Ameristar M951P 95% upflow single-stage: M951P040BU24AAA, M951P040BU24AAB, M951P060BU36AAA, M951P060BU36AAB, M951P080BU42AAA, M951P080BU42ABA, M951P080BU42ABB, M951P100CU48AAA, M951P100DU60AAA, M951P120DU60AAA
- American Standard AUH1: AUH1B040A9241AA/AB, AUH1B060A9361AA/AB, AUH1B080A9421AA/BA/BB, AUH1C080A9601AA, AUH1C100A9481AA, AUH1D100A9601AA, AUH1D120A9601AA
- Trane TUH1 equivalents of the AUH1 models above
- ADD series single-stage condensing furnaces (ADD040, ADD060, ADD080, ADD100)
Match the part number on the existing board before ordering. This board is for 120V ignitors. Confirm the furnace model and production year, and do not use it on early downflow units that call for KIT18109 or CNT07943. Power must be off and the 5 amp fuse checked before the board is condemned.
Genuine OEM parts
Easy online ordering
30-day hassle-free returns
Help when you need it
- Direct Replacement — Replaces CNT07541 and related earlier boards.
- Full Heat Sequence — Runs the heat sequence, monitors limits and the pressure switch, and switches inducer, gas valve, ignitor and blower.
- LED Diagnostics — LED status and fault indication aids troubleshooting.
- Protected Circuit — Includes an on-board 5 amp fuse.